Features:
- Ultra Low Attenuation
- Copper Shield
- Low VSWR
- Wide Frequency Range
- Excellent Power Rating
- UV Resistant
- Gas Block or Gas Pass
Materials and Dimensions |
|
Inner conductor-helicat corrugated copper |
9.25 mm / .364 in |
Dialectric-foam PE |
22.8 mm / .898 in |
Outer conductor- corrugated copper tube |
24.7 mm / .972 in |
Diameter over outer jacket- polythylene black |
27.4 mm / 1.079 in |
Mechanical Specifications |
|
Cable Weight |
425 kg/km (approx.) |
Tensile Strength |
1450 N | 325 lbs. |
Min. Bending Radius (single) |
120 mm | 4.72 in |
Min. Bending Radius (repeated) |
250 mm | 9.84 in |
Number of bends, minimum (typical) |
15 (50) |
Recommended Hanger Spacing |
1.0 m | 3 ft. |
Environmental Specifications |
|
Installation Temperature |
-25°C to +60°C |
Operating Temperature |
-40°C to +85°C |
Storage Temperature |
-70°C to +85°C |
2002/95/EC (RoHS) |
compliant |
Return Loss |
|
1 to 1000 MHz |
Return Loss: ≤-26 dB | VSWR: ≤ 1.105:1 |
1000 to 1900 MHz |
Return Loss: ≤-26 dB | VSWR: ≤ 1.105:1 |
1900 to 2200 MHz | Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 |
2200 to 2500 MHz | Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 |
2500 to 3800 MHz | Return Loss: ≤-24 dB | VSWR: ≤ 1.140:1 |
Electrical Specifications |
|
Impedance |
50 ± 1 Ω |
Relative Velocity of Propogation |
89% |
Capacitance (1kHz) |
73.5 ± 1.5 pF/m |
Maximum Operating Frequency |
5.3 GHz |
Peak Power Rating |
95 kW |
Insulation Resistance |
≥ 10 GΩ x km |
Operating Voltage |
3000 Vrms |
DC Breakdown Voltage |
10000 V |
Jacket Spark Test Voltage |
6300 Vrms |
Inner Conductor DC-resistance |
≤ 1.55 Ω /km |
Outer Conductor DC-resistance |
≤ 1.40 Ω /km |
Attenuation |
||
Frequenxy (MHz) |
Attenuation (dB/100m) |
Average Power (kW) |
1 | 0.10 | 84 |
100 | 1.12 | 8.9 |
150 |
1.37 |
7.1 |
450 |
2.45 |
3.97 |
824 |
3.42 |
2.86 |
900 |
3.56 |
2.72 |
1000 |
3.78 |
2.57 |
1700 |
5.17 |
1.91 |
1800 |
5.25 |
1.84 |
1900 |
5.41 |
1.79 |
2000 |
5.58 |
1.7 |
2200 |
5.89 |
1.65 |
2500 |
6.34 |
1.53 |
3000 |
7.06 |
1.37 |
3500 |
7.73 |
1.25 |
3800 |
8.12 |
1.18 |
Standard Conditions |
|
Attenuation, Ambient Temperature |
20̊ C |
Average Power, Ambient Temperature |
40̊ C |
Average Power, Inner Conductor Temperature |
100̊ C |
Ordering Information |
||
Part Number |
Description |
UOM |
AAT-78-FC |
7/8” 50 ohm Coaxial Cable |
Per Ft. |
Disclaimer: Specifications are subject to change without notice. Information may be changed or updated without notice. American Amplifier TechnologiesTM may also make improvements and/or changes in the products and/or pricing described at any time without notice.